The problem
This company has many glass furnaces with fans running inefficiently and at high speed causing problems with material fatigue on the impellers and catastrophic breakdowns.
Our solution
After attending site to establish volume and pressure readings, we supplied 4 new 400kW fans (2 operating in series) to produce 20% more pressure for the highest pressure requirement and at the normal operating pressure save them power. As well as reducing the speed to half the original speed eliminating the regular breakdown occurrence.
The result
As well as eliminating breakdowns, the change of fans has resulted in energy savings of around 40%, giving a return on investment in just over one year. We have now completed three furnaces with many more to look at.
Get in touch to find out how we can ensure your fan units are running as efficiently as possible: 0121 561 4615 / info@industrialfanservices.co.uk